Dual Flange Static Torque Transducer CL1 98 0.2Nm-50kNm

The product consists of a resistance strain as a sensitive element and an integrated circuit. The range of this product is 0.2Nm-50kNm. The material of this product is stainless steel, alloy steel, or aluminum alloy. The shell material is aluminum.

  • Easy to install and use
  • Dual flange connection
  • High precision
  • Stable and reliable performance
  • Wide range: 0.2Nm-50kNm
  • Applicable to static torque measurement

Introduction to the Static Torque Transducer

The dual-flange static torque transducer has good stability and strong anti-interference ability. The flange structure is easy to install. It measures static torque and non-continuous rotation torque value. It is used in various torque testers, torque wrenches and other static torque measurement fields. It adopts the principle of resistance strain type, which can be stable and reliable

dual flange static torque transducer

Read More Torque Sensor.

Dual Flange Static Torque Transducer Parameters

Measuring range: 0Nm—100000Nm, optional 150,000Nm, 200,000Nm, 500,000Nm, 1,000,000Nm, customizable, special range customizable.
Connection mode: Flange
Frequency response: 100μs
Supply voltage: 12~24VDC
Output signal: 4~20mA, 1~5V, 5~15Khz (optional)
Output impedance: 1000Ω±5Ω
Static overload: 120%
Torque accuracy: <±0.5 % F· S, <±0.2 % F· S, <±0.1 % F· S (optional)
Nonlinearity: <±0.2 % F· S
Repeatability: <±0.1% F· S
Return error: <0.1 % F· S
Zero time drift: <0.2 % F· S
Zero temperature drift: <0.2 % F· S /10℃
Insulation impedance: >250MΩ
Using temperature: -10 ~ 50℃
Storage temperature: -20 ~ 70℃
Current consumption: <150mA

 

dual flange static torque transducer

 

Range (Nm) A B φC φD φE F φG M
0-100 85 10 59 22 12 5 49 4-φ6.5
0-1000 95 20 98 40 20 6 80 8-φ10.5
0-50000 95 20 125 50 40 6 105 8-φ12.5
0-10000 160 30 190 80 30 6 160 8-φ19
0-5000 220 45 308 130 80 5 250 12-φ26

 

Get a Quote Now

Sino-Inst’s measuring range is 0.5Nm-50kNm. This product supports customization and OEM. Sino-Inst’s products have a one-year warranty. The dual-flange static torque sensor is suitable for a variety of occasions. Our products comply with ISO9001 international certification.

The dual flange static torque transducer has been tested many times. It can meet your various measurement needs. Sino-Inst has dozens of static torque transducers. Our professional engineers can recommend the right torque measuring instrument for you. If you have any questions, please feel free to contact us.

Contact Form Demo (#3)
Products Categories
Get A Free Quote
Contact Form Demo (#3)

Applications of Dual-Flange Static Torque Transducer

1. Detection of output torque and power of rotating power equipment. such as motors, engines, internal combustion engines;

2. Detection of torque and power of fans, water pumps, gearboxes, and torque wrenches;

3. Detection of torque and power in railway locomotives, automobiles, tractors, aircraft, ships, and mining machinery;

4. It can be used for torque and power detection in sewage treatment systems.

5. It can be used to manufacture viscometers;

6. It can be used in process industries;

7. It can be used in laboratories, testing departments, production monitoring and quality control.

dual flange static torque transducer

More Detail

What is the Difference between Single Flange and Dual Flange?

Single flange means that the positive pressure side of the transmitter is a flange structure. It is directly connected to the interface of the measuring medium. On the negative pressure side, the pressure pipe is used to connect the measuring medium to the chamber of the transmitter.

The advantage is high measurement accuracy. It can achieve the measurement technical indicators of the transmitter.

The disadvantage is that the negative pressure pipeline must be sealed. And the transmitter needs to be range-shifted. The error of the medium liquid in the negative pressure pipeline should be migrated during calibration.

Double flange means that both the positive and negative pressure sides of the transmitter are flange structures. It can be directly connected to the container and pipeline to be measured.

The advantage is easy installation and convenient calibration. No range migration is required.

The disadvantage is low measurement accuracy. Since the flange and the transmitter are connected by an elastic hose. The inside should be filled with silicone oil.

Therefore, there is a certain deviation in the transmission of medium pressure changes. The external temperature change has some influence on the silicone oil. Therefore, there is a certain error in the measurement reflection.

Disc Flange Torque Sensor

What are the Main Types of Flanges?

1. Plate Slip-On Flange

2. Neck Slip-On Flange

3. Neck Butt Weld Flange

4. Integral Flange

5. Socket Weld Flange

6. Threaded Flange

7. Butt Weld Loose Flange

8. ANSI Neck Butt Weld Flange

9. ANSI Neck Slip-On Flange

10. Lined Flange Cover

11. Flange Cover

12. Slip-On Loose Flange

Related Products

Related News

Rotary torque sensors can measure the torque generated by rotating objects during operation. It provides key data for system control, […]

Torque sensors are very important in industrial manufacturing. The following is a detailed introduction from the aspects of principle, types, […]

A differential pressure sensor is used to measure the difference between two pressures. It uses a differential pressure measuring element. […]

There are many things to note when installing flow switches and flow sensors. Proper installation of flow switches and flow […]

 Oxygen flow meters are medical devices used to measure oxygen flow in hospitals. Its main function is to supply oxygen […]

A flow switch is an instrument used to control the flow of a medium (gas, liquid, oil) flowing through a […]

Liquefied Petroleum Gas (LPG) Definition Liquefied petroleum gas is a colorless volatile liquid obtained by pressurizing and cooling natural gas […]

What is hydrostatic pressure? Hydrostatic pressure is the pressure exerted by a stationary fluid due to the effect of gravity. […]

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)